Application
The battery short-circuit tester is designed according to the requirements of various battery short-circuit test standards. According to the standard, the short-circuit device must meet the internal resistance range of 80mΩ±20 or ≤10mΩ to obtain the maximum short-circuit current required by the test. This machine is used to simulate the external short circuit of the battery or battery pack/battery pack sample, and judge its safety through its phenomenon.

Standards
GB 31241-2014, UL 2540-2013, UL 1642, UL 2054, UN38.3, IEC62133-2017

Key Specification
Model GT-I09
Impact voltage AC 1kv/1.2-50μs(peak)1min
Maximum testing voltage 0~100V
DC response time ≤5μs
Maximum short circuit current 0-1000A
Interior resistance 80±20mΩ or ≤5mΩ or < 20mΩ or 30± 10mΩ
Action time Response time / release time ≯30ms
Performance characteristic Cold and voltage ≯66%Us Cold release voltage ≯30%Us,≮5%Us
Mechanical life 300k times
Test chamber temperature range RT + 10~100 ℃
Temperature control accuracy 0.1℃
Temperature uniformity ± 2 ℃
Temperature fluctuation ± 0.5 ℃